Search results for "Time resolution"
showing 10 items of 38 documents
A 3-Year Sample of Almost 1,600 Elves Recorded Above South America by the Pierre Auger Cosmic-Ray Observatory
2020
The time and location of the 1,598 verified and reconstructed elves, used for the analysis showcased in this paper, are publicly available on the website of the Pierre Auger Observatory (https://www.auger.org/ index.php/science/data). We wish to thank the World Wide Lightning Location Network (http://wwlln.net), a collaboration among over 50 universities and institutions, for providing the lightning location data used in this paper. We acknowledge Robert Marshall for providing one of the most advanced elve simulations to the public, a key tool in understanding the elves observed by the Pierre Auger Observatory. The successful installation, commissioning, and operation of the Pierre Auger Ob…
Pulsating in Unison at Optical and X-Ray Energies: Simultaneous High Time Resolution Observations of the Transitional Millisecond Pulsar PSR J1023+00…
2019
PSR J1023+0038 is the first millisecond pulsar discovered to pulsate in the visible band; such a detection took place when the pulsar was surrounded by an accretion disk and also showed X-ray pulsations. We report on the first high time resolution observational campaign of this transitional pulsar in the disk state, using simultaneous observations in the optical (TNG, NOT, TJO), X-ray (XMM-Newton, NuSTAR, NICER), infrared (GTC) and UV (Swift) bands. Optical and X-ray pulsations were detected simultaneously in the X-ray high intensity mode in which the source spends $\sim$ 70% of the time, and both disappeared in the low mode, indicating a common underlying physical mechanism. In addition, o…
Deaf readers benefit from lexical feedback during orthographic processing
2019
Published: 23 August 2019 It has been proposed that poor reading abilities in deaf readers might be related to weak connections between the orthographic and lexical-semantic levels of processing. Here we used event related potentials (ERPs), known for their excellent time resolution, to examine whether lexical feedback modulates early orthographic processing. Twenty congenitally deaf readers made lexical decisions to target words and pseudowords. Each of those target stimuli could be preceded by a briefly presented matched-case or mismatched-case identity prime (e.g., ALTAR-ALTAR vs. altar- ALTAR). Results showed an early effect of case overlap at the N/P150 for all targets. Critically, thi…
Absolute optical chiral analysis using cavity-enhanced polarimetry
2021
Chiral analysis is central for scientific advancement in the fields of chemistry, biology, and medicine. It is also indispensable in the development and quality control of chiral compounds in the chemical and pharmaceutical industries. Current methods for chiral analysis, namely optical polarimetry, mass spectrometry and nuclear magnetic resonance, are either insensitive, have low time resolution, or require preparation steps, and so are unsuited for monitoring chiral dynamics within complex environments: the current need of both research and industry. Here we present the concept of absolute optical chiral analysis, as enabled by cavity-enhanced polarimetry, which allows for accurate unambi…
Effects of Repeating a Tactile Brain-Computer Interface on Patients with Disorder of Consciousness: A Hint of Recovery?
2019
Brain-computer interface (BCI) has been emerging as an assessment tool for patients with disorder of consciousness (DOC). With the advantages of high time resolution, low cost and portable design, EEG based BCI systems are especially suitable for bedside measurement. Recent studies showed the successful application of an EEG based BCI on DOC assessment and communication. However, the effect of repeated BCI measurement on this patient group is not clear. In this study, a tactile BCI paradigm was repeated 12 runs for 10 consecutive days on 5 DOC patients. Although the BCI performance varied among runs and days, every patient reached at least once the accuracy above 60%. Moreover, the Coma Rec…
Beam test results of IHEP-NDL Low Gain Avalanche Detectors(LGAD)
2020
A High-Granularity Timing Detector (HGTD) is proposed based on the Low-Gain Avalanche Detector (LGAD) for the ATLAS experiment to satisfy the time resolution requirement for the up-coming High Luminosity at LHC (HL-LHC). We report on beam test results for two proto-types LGADs (BV60 and BV170) developed for the HGTD. Such modules were manufactured by the Institute of High Energy Physics (IHEP) of Chinese Academy of Sciences (CAS) collaborated with Novel Device Laboratory (NDL) of the Beijing Normal University. The beam tests were performed with 5 GeV electron beam at DESY. The timing performance of the LGADs was compared to a trigger counter consisting of a quartz bar coupled to a SiPM read…
The Lightfield Microscope Eyepiece
2021
Lightfield microscopy has raised growing interest in the last few years. Its ability to get three-dimensional information about the sample in a single shot makes it suitable for many applications in which time resolution is fundamental. In this paper we present a novel device, which is capable of converting any conventional microscope into a lightfield microscope. Based on the Fourier integral microscope concept, we designed the lightfield microscope eyepiece. This is coupled to the eyepiece port, to let the user exploit all the host microscope’s components (objective turret, illumination systems, translation stage, etc.) and get a 3D reconstruction of the sample. After the optical design, …
Future use of silicon photomultipliers for Kaos at MAMI and P¯ANDA at FAIR
2009
A characterisation of scintillating fibres with silicon photomultiplier read-out was performed in view of their possible application in fibre tracking detector systems. Such a concept is being considered for the Kaos spectrometer at the Mainz Microtron MAMI and as a time-of-flight start detector for the hypernuclear physics programme at the PANDA experiment of the FAIR project. Results on particle detection effciency and time resolution are discussed. In summary, the silicon devices are very suitable for the detection of the low light yield from scintillating fibres insofar a trigger scheme is found to cope with the noise rate characteristics.
Variations in Substitution Rate in Human and Mouse Genomes
2003
We present a method to quantify spatial fluctuations of the substitution rate on different length scales throughout genomes of eukaryotes. The fluctuations on large length scales are found to be predominantly a consequence of a coarse-graining effect of fluctuations on shorter length scales. This is verified for both the mouse and the human genome. We also found that both species show similar standard deviation of fluctuations even though their mean substitution rate differs by a factor of two. Our method furthermore allows to determine time-resolved substitution rate maps from which we can compute auto-correlation functions in order to quantify how fast the spatial fluctuations in substitu…
High-resolution records of past and modern Pb exposure: Laser-ablation ICPMS profiles from tooth enamel
2006
We present compositional and isotopic profiles of past and modern tooth enamel aimed at reconstructing in-vivo Pb exposure at high spatial and time resolution. Focus is on dental enamel because of its sequential mineralization preserving time-series information, and due to its resistance to post-mortem diagenetic alteration. Examples include medieval Pb–Ag miners from SW Germany (Black Forest), the port of ancient Rome (Isola Sacra) for an assessment of the ‘Pb poisoning hypothesis’, and a modern Pb–Zn smelter village in NE NSW. (Sub-)ppb levels of U, LREEs, Y in soil-buried enamel resembling modern enamel are utilized as indicators for the preservation of pristine in-vivo concentrations. T…